SciELO - Scientific Electronic Library Online

 
vol.26 número1FACTORES DE RIESGO ASOCIADOS A INFECCIONES INTRAHOSPITALARIAS EN EL PACIENTE CRÍTICOCORRELACION CITOLÓGICA, COLPOSCÓPICA E HISTOLÓGICA DE LESIONES PRECANCERÍGENAS EN CÉRVIX índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Journal

Artigo

Indicadores

Links relacionados

  • Não possue artigos similaresSimilares em SciELO

Compartilhar


Revista Médica La Paz

versão On-line ISSN 1726-8958

Resumo

CRISPIN NINA, Deyssi  e  DURAN CALLE, Juan José. CORRELATION OF β-HCG LEVELS AND INTRA-OPERATIVE ULTRASONOGRAPHY IN ECTOPIC PREGNANCY. Rev. Méd. La Paz [online]. 2020, vol.26, n.1, pp.18-23. ISSN 1726-8958.

Introduction: The diagnosis for ectopic pregnancy may be difficult, and must be carried out quickly and safely since a delay can lead to rupture, bleeding and endanger the life of the patient. Objective: To determine the correlation degree of β-hCG levels and ultrasonography with the intra-operative findings of patients with ectopic pregnancy diagnosis in the Gynecology and Obstetrics Service at Hospital Municipal Boliviano Holandés. Material and methods: Descriptive, cross-sectional and retrospective study that included 115 patients with ectopic pregnancy diagnosis, and admitted in the Obstetrics and Gynecology Service at Hospital Municipal Boliviano Holandés during the period 2010-2014. Results: The most frequently affected population was 20 to 30 years old (88.7%). Most of the cases were observed during 2014 (47%). Validity of ultrasound findings reflected 98.2% of sensitivity and 75 % of specificity. Safety of ultrasound findings reflected Positive Predictive Value of 99.1 % and Negative Predictive Value of 60 %. Validity of ultrasound findings combined with β-hCG serum quantification displayed a sensitivity of 99.1 % and specificity of100%. Safety of ultrasound findings combined with β-hCG serum quantification displayed a Positive Predictive Value of 100 % and Negative Predictive Value of 80 %. Conclusions: The ultrasonographic diagnostic test combined with the β-hCG serum quantification has better validity and safety than the ultrasonographic test alone.

Palavras-chave : -hCG; ultrasonography; ectopic pregnancy.

        · resumo em Espanhol     · texto em Espanhol     · Espanhol ( pdf )

 

Creative Commons License Todo o conteúdo deste periódico, exceto onde está identificado, está licenciado sob uma Licença Creative Commons